Raymarine NMEA BRIDGE Specifikace Strana 11

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 23
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 10
S e a T a l k < - > N M E A
S e a T a l k < - > R S 2 3 2
C o n v e r t e r
SeaTalk Output
The converter periodically checks if any new data has arrived from NMEA, that needs to
be sent to SeaTalk. New data is written to the SeaTalk bus only if the bus is not in use by
any other instrument. If the bus is in use, the converter waits for a while, and tries again.
Collision detection
With SeaTalk it can happen, that two instruments try to send data at the same time. This
may causes a data collision on the SeaTalk bus. In this case, the SeaTalk NMEA Bridge
immediately stops sending the current datagram.
To detect data collision, every single bit sent out to the SeaTalk bus is read back again
and checked for successful transmission. If the transmission was corrupted, this
transmission is stopped immediately. This single datagram will be discarded.
When the bus becomes free again, the transmission will be started again.
The lost datagram will be repeated on the next update from NMEA data.
At this time the following SeaTalk datagrams can be sent
00 Depth
10 app. Wind angle
11 app. Wind speed
25 Total & Trip mileage
27 Water temperature
30 Display illumination
50 Latitude
51 Longitude
52 Speed over ground
53 Course over ground
54 Time
56 Date
82 Target waypoint name
85 Navigation to waypoint Data
89 Compass ST40 heading
A2 Waypoint arrival Info
20 Speed through water
(see “Configuration settings” Item 14)
© 2004-2010 All Rights Reserved HW Version 3.5 GI/ SW Version 1.62 http://www.gadgetPool.de
Page 11 of 23 FWa[email protected]